Features
- Simple Dashboard providing system health and operation at a glance.
- Open and Close switches
- Location map showing all meters and their current state, online, offline, power outage and switch status
- Outage Management System by distribution transformer and feeder
- Reporting Capabilities with more than 16 reports as well as the ability to custom design a report.
- Custom API for interfacing with billing software including MultiSpeak connectivity
- Transformer Loading Tools
- View collected data as received
- Outage and Alarm Notification sent by email or test as they occur
- Load Profile available on all meters and included at no additional charge
- Search database for devices by Account Number, Meter Serial Number and Address
- Power over Ethernet (PoE) monitoring
- Every packet delivered to the system includes KWh delivered and received, KW, KVARh, KVAR, volts and amps on all three phases, power factor, frequency and meter temperature.
Specifications
- Forms 1S, 2S, 12/25S available with 200amp switch.
- All meter forms are available.
- Switches for Class 320 available in 2021.
- Accuracy better than 0.2%.
- Last Gasp capacitors good for 20+ seconds.
- 400 Event Log.
- Time of Use.
- 12 Channels of Load Profile.
- Net Metering.
- 4 Quadrant Metering.
- Reactive & Demand.
- All LoRa meters are time synced at midnight and immediately after a power outage.
- Alerts and Alarms
- 32-digit security key
- 2020 programming software available with purchase of meters.
- 2 Year warranty on meters
- ANSI C12.20, C12.18 & C12.19 Compliant
- Communicate with end devices up to 20 miles away.
- Completely open system – multiple vendors for every aspect.
- Standards based system controlled by the LoRa Alliance®.
- Lowest cost infrastructure.
- Point to point/multipoint system (no mesh).
- Complete Plug & Play system. Very little prep work required.
- Security from end to end is provided using AES 128.
- Single page Dashboards to display systems health of Electric, Water and Gas
- Mapping System to show all meter location based on Electric, Water and Gas
- Data packets can be transmitted in intervals from 1 minute to 1 hour. Each packet can contain 13 to 14 variables and typically, KWh delivered & received, KW, KVArh, KVAr,
- Volts and Amps on all three phases, Power Factor, Meter
- Temperature and Frequency.
- 2 + channels of load profile are transmitted every 20 minutes and generally, include 15-minute KWh and KVArh.
- Current limiting feature is available to control customer usage during cold weather.
- Prepaid options available in End Sight or third-party software.
- Net Metering options include Delivered, Received, delivered + Received (Secure) and Delivered – Received (Net)
- Demand can be manually or automatically reset from the Head End system based on Cycle Day
- Voltage Sag & Swell events programmable for magnitude and duration.
- Security and Theft of service notifications.
Reviews